Support & Resources

+1

ExoBrite™ CD81 (Mouse/Rat) Flow Antibody

Validated antibody for optimal detection of EV marker CD81 from mouse or rat in purified or bead-bound EVs by flow cytometry.

Conjugation
Size
Catalog #
price
Qty
25 tests
100 tests
Clear selection
ADD TO CART
(Please select quantity above )

Wishlist updated! View wishlist

Product Description

ExoBrite™ CD81 (Mouse/Rat) Flow Antibody has been validated by Biotium for detection of EV marker CD81 from mouse or rat in isolated EVs. The antibody conjugates offer exceptional signal-to-noise and include color options for the Pacific Blue™, FITC, and PE channels.

  • NEW: Now with updated buffer formulation for improved signal-to-noise
  • Optimal detection of mouse or rat CD81 EV marker by flow cytometry
  • Validated for purified or bead-bound EVs
  • Bright signal and low background
  • Available in 3 colors

The most common proteins used as EV markers are CD9, CD63, and CD81, members of the tetraspanin family. These tetraspanins are broadly expressed on many cell types and can therefore be detected on many types of EVs, but their expression levels vary depending on the cell type of origin.

EV antibodies you can trust

Other commercially available antibodies for tetraspanin proteins CD9, CD63, and CD81 are generally not validated for isolated EVs and may require tedious optimization for your EV prep and staining protocol. The antibodies and dye labels of ExoBrite™ Flow Antibody Conjugates were carefully selected and validated for robust detection of isolated EVs. In addition, the antibodies are provided in a proprietary buffer formulation for reduced antibody aggregation and brighter EV staining for optimal accuracy and signal-to-noise.

For general EV staining, Biotium’s ExoBrite™ True EV Membrane Stains offer unparalleled coverage of EVs in a sample and address issues of dye aggregation often seen with PKH and other common membrane dyes. Biotium also offers optimized ExoBrite™ EV Surface stains conjugated to cholera toxin B (CTB)wheat germ agglutinin (WGA), and Annexin V. These stains are specially formulated for bright and specific detection of isolated EVs by flow cytometry. These ExoBrite™ EV Surface stains may also be combined with antibody staining, for multi-parameter analysis.

Biotium also offers conjugated ExoBrite™ Western Antibodies against CD9CD63, and CD81 designed for optimal detection in EV extracts by fluorescent western blot.

Note: In our testing, we have found that ExoBrite™ 490/515 dye may bind to streptavidin coated surfaces or beads if free biotin binding sites are not blocked. We recommend performing a biotin blocking step after binding your biotinylated capture antibody to streptavidin beads or surfaces when using ExoBrite™ 490/515 conjugates. Alternatively, consider using a different ExoBrite™ dye for staining EVs captured on streptavidin beads or surfaces.

ExoBrite™ Flow Antibody Conjugates

AntibodyEx/EmDetection ChannelSizeCatalog No.
ExoBrite™ 410/450
CD9 Flow Antibody
416/452 nmPacific Blue ™25 testsP003-410-125
100 testsP003-410-500
ExoBrite™ 490/515
CD9 Flow Antibody
490/516 nmFITC25 testsP003-490-125
100 testsP003-490-500
ExoBrite™ 560/585
CD9 Flow Antibody
562/584 nmPE25 testsP003-560-125
100 testsP003-560-500
ExoBrite™ 650/665
CD9 Flow Antibody
652/668 nmAPC25 testsP003-650-125
100 testsP003-650-500
ExoBrite™ R-PE
CD9 Flow Antibody
496, 546, 565/578PE25 testsP003-RPE-125
100 testsP003-RPE-500
ExoBrite™ 410/450
CD9 (Mouse) Flow Antibody
416/452 nmPacific Blue ™25 testsP018-410-125
100 testsP018-410-500
ExoBrite™ 490/515
CD9 (Mouse) Flow Antibody
490/516 nmFITC25 testsP018-490-125
100 testsP018-490-500
ExoBrite™ 560/585
CD9 (Mouse) Flow Antibody
562/584 nmPE25 testsP018-560-125
100 testsP018-560-500
ExoBrite™ 650/665
CD9 (Mouse) Flow Antibody
652/668 nmAPC25 testsP018-650-125
100 testsP018-650-500
ExoBrite™ 410/450
CD63 Flow Antibody
416/452 nmPacific Blue ™25 testsP004-410-125
100 testsP004-410-500
ExoBrite™ 490/515
CD63 Flow Antibody
490/516 nmFITC25 testsP004-490-125
100 testsP004-490-500
ExoBrite™ 560/585
CD63 Flow Antibody
562/584 nmPE25 testsP004-560-125
100 testsP004-560-500
ExoBrite™ R-PE
CD63 Flow Antibody
496, 546, 565/578PE25 testsP004-RPE-125
100 testsP004-RPE-500
ExoBrite™ 410/450
CD63 (Mouse) Flow Antibody
416/452 nmPacific Blue ™25 testsP022-410-125
100 testsP022-410-500
ExoBrite™ 490/515
CD63 (Mouse) Flow Antibody
490/516 nmFITC25 testsP022-490-125
100 testsP022-490-500
ExoBrite™ 560/585
CD63 (Mouse) Flow Antibody
562/584 nmPE25 testsP022-560-125
100 testsP022-560-500
ExoBrite™ 410/450
CD81 Flow Antibody
416/452 nmPacific Blue ™25 testsP005-410-125
100 testsP005-410-500
ExoBrite™ 490/515
CD81 Flow Antibody
490/516 nmFITC25 testsP005-490-125
100 testsP005-490-500
ExoBrite™ 560/585
CD81 Flow Antibody
562/584 nmPE25 testsP005-560-125
100 testsP005-560-500
ExoBrite™ R-PE
CD81 Flow Antibody
496, 546, 565/578PE25 testsP005-RPE-125
100 testsP005-RPE-500
ExoBrite™ 410/450
CD81 (Mouse/Rat) Flow Antibody
416/452 nmPacific Blue ™25 testsP019-410-125
100 testsP019-410-500
ExoBrite™ 490/515
CD81 (Mouse/Rat) Flow Antibody
490/516 nmFITC25 testsP019-490-125
100 testsP019-490-500
ExoBrite™ 560/585
CD81 (Mouse/Rat) Flow Antibody
562/584 nmPE25 testsP019-560-125
100 testsP019-560-500
ExoBrite™ 410/450 IgG1
Isotype Control Flow Antibody
416/452 nmPacific Blue ™25 testsP008-410-125
100 testsP008-410-500
ExoBrite™ 490/515 IgG1
Isotype Control Flow Antibody
490/516 nmFITC25 testsP008-490-125
100 testsP008-490-500
ExoBrite™ 560/585 IgG1
Isotype Control Flow Antibody
562/584 nmPE25 testsP008-560-125
100 testsP008-560-500
ExoBrite™ R-PE IgG1
Isotype Control Flow Antibody
496, 546, 565/578PE25 testsP008-RPE-125
100 testsP008-RPE-500
ExoBrite™ 650/665 IgG1
Isotype Control Flow Antibody
652/668 nmAPC25 testsP003-650-125
100 testsP003-650-500
 

You may also like…